Scaffold tie and height-to-base calculator

Enter a supported scaffold's height, base width and length and get its height to base ratio, whether it must be restrained from tipping, and where the ties go. Every figure names the paragraph of 29 CFR 1926.451 it comes from.

Height-to-base ratio and tie plan

Enter the dimensions of a supported scaffold in feet. Base width includes outrigger supports if used. Intended load is optional.

Height to base width ratio, height ÷ base (1926.451(c)(1))
12 : 1
Restraint against tipping
Required: the ratio is more than 4:1 (1926.451(c)(1))
First tie, closest horizontal member to the 4:1 height = 4 × base, (c)(1)(ii)
20 ft
Repeat vertically every 26 ft or less, base wider than 3 ft, (c)(1)(ii)
At least 2 levels
Top tie no further than the 4:1 height from the top, so at or above, (c)(1)(ii)
40 ft
Ties per level: each end, and no more than 30 ft apart, (c)(1)(ii)
4
Ties in all
8
Tie levels, highest allowed height for each. Tie lower where a horizontal member sits; ties placed lower can need more levels than shown.
LevelAt or below (ft)Ties on this level
1204
2464

Ties and guys go where horizontal members support both the inner and outer legs, (c)(1)(i). Use the manufacturer's tie instructions where they exist.

Studying for CHST? Take the free 10-question check to see exactly which topics to fix first, then close the gaps with the Toe Board course.

The rule in plain words

The tipping rule is 29 CFR 1926.451(c)(1), for supported scaffolds. Height is measured against the base width, counting outrigger supports if used. We give the rule in our own words; read the paragraph itself for the exact text.

  • Ratio = height ÷ base width. Restraint by guying, tying, bracing or an equivalent means is required when the ratio is more than 4 to 1, (c)(1). Exactly 4 to 1 does not trigger it.
  • First tie at 4 × base width. That is the 4:1 height. The tie goes at the closest horizontal member to it, or where the manufacturer says, (c)(1)(ii).
  • Repeat every 20 ft or less for a base 3 ft wide or less, every 26 ft or less for a wider base. Each repeat is at a horizontal member, (c)(1)(ii).
  • Top tie no further than the 4:1 height from the top. So the highest tie is at or above height minus 4 × base width, (c)(1)(ii).
  • Ties at each end and every 30 ft or less along the length. The 30 ft is measured from one end toward the other, (c)(1)(ii). Ties per level = length ÷ 30, rounded up, plus 1.
  • Placement. Ties go where horizontal members support both the inner and outer legs, (c)(1)(i).
  • Capacity. In general, each scaffold and component must support its own weight and at least 4 times the maximum intended load, 1926.451(a)(1); exceptions are in (a)(2) to (a)(5) and (g). The calculator multiplies your load by 4, so enter the load in the unit you want back.

Ties are also required, whatever the ratio, wherever an eccentric load such as a cantilevered work platform acts on a supported scaffold, (c)(1)(iii).

Worked example 1: 40 ft high on a 5 ft base

Ratio = 40 ÷ 5 = 8:1, which is more than 4:1, so restraint is required. The 4:1 height is 4 × 5 = 20 ft, so the first tie is at 20 ft. The top tie must be at or above 40 − 20 = 20 ft, and the first tie already is, so one level is enough. On a 30 ft long scaffold that is 30 ÷ 30 = 1, plus 1, so 2 ties.

Worked example 2: 60 ft high on a 5 ft base, 70 ft long

Ratio = 60 ÷ 5 = 12:1. First tie at 4 × 5 = 20 ft. The base is wider than 3 ft, so the next level is within 26 ft of the first, at 46 ft or below. The top tie must be at or above 60 − 20 = 40 ft, and 46 ft is, so two levels do it. Along 70 ft: 70 ÷ 30 = 2.33, rounded up to 3, plus 1 is 4 ties per level, so 8 in all. With a 500 lb intended load, the capacity needed is 4 × 500 = 2,000 lb.

Worked example 3: why 3 ft and 3.1 ft differ

The spacing switches at a 3 ft base. A 3 ft wide scaffold 80 ft high has its first tie at 12 ft, then every 20 ft or less: 32, 52 and 72 ft or below, and the top tie must be at or above 80 − 12 = 68 ft. A 3.1 ft wide scaffold of the same height has its first tie at 12.4 ft, then every 26 ft or less: 38.4 ft, 64.4 ft, and then the top. The sizes are invented. These are original arithmetic examples, not exam questions.

How this shows up in CHST study

The CHST blueprint covers working at heights in its first domain, so it is worth knowing which number applies. Be able to say that 4:1 is the trigger for restraint, that the first tie goes at 4 times the base width, that 20 and 26 feet depend on whether the base is 3 feet wide or less, and that capacity is a factor of 4 on the intended load. See the scaffolds (Subpart L) guide for the rest of Subpart L, the ladder angle calculator for the other 4 to 1 rule, and the fall protection (Subpart M) guide.

Scaffold tie questions

Is a scaffold at exactly 4:1 tied?

Not under 1926.451(c)(1). That paragraph requires restraint when the height to base width ratio is more than four to one, so exactly 4:1 does not trigger it. The manufacturer's instructions can still call for ties, and (c)(1)(iii) requires ties, guys, braces or outriggers whenever an eccentric load such as a cantilevered platform acts on the scaffold.

Does the base width include outriggers?

Yes. Paragraph (c)(1) measures height against the base width including outrigger supports, if used. Enter the width at the ground that includes them. Our suggestion, not the rule: use the narrowest base the scaffold has.

Where does the first tie go?

At the closest horizontal member to the 4:1 height, or where the manufacturer's recommendations place it. The 4:1 height is four times the base width. The calculator shows that height as the highest the first tie can sit, because a tie goes at a horizontal member.

Does this apply to mobile scaffolds?

Mobile scaffolds have their own paragraph, 1926.452(w). This tool applies the supported scaffold rule in 1926.451(c)(1) and does not replace it. Read paragraph (w) for a mobile scaffold.

Divide the height by the base width to get the ratio. Above 4:1, the first tie goes at 4 times the base width, more tie levels repeat every 20 or 26 feet until the top tie is within the 4:1 height of the top, and each level is tied at both ends and every 30 feet or less. A calculation aid for 29 CFR 1926.451(c)(1); the manufacturer's tie instructions and a competent person govern on site.

Try one free question

Try one question

Question 1 of the free 10-question check on CHST. No signup.

Question 1 of 10 · free checkUntimed

Emergency Preparedness, Incident Investigation, and Response

On a building under construction, what is the longest allowed travel distance from any point of the protected area to the nearest fire extinguisher?

Choose an answer to begin

Free CHST study plan

A week-by-week plan from today to your exam, weighted to the published exam outline. We show it here and email you a copy.

Ask Kick before you buy AI your Toe Board study buddy

See what's on the CHST exam, test yourself with 5 quick questions, or find the plan that fits you.

Published references

Rule text read on the eCFR on 25 Oct 2026, current to the 22 Oct 2026 issue.